Call 08048968458100% Response Rate
Send E-mail

Thermocouple Wire

Manufacturer of a wide range of products which include ptfe-fiber glass-fiber glass, fep-almyler screen-fep-ss braiding insulated, pfa insulated cable, polyimide-ptfe-polyimide-ptfe-mica-fg-ss braiding insulated, ptfe-mica-fiber glass insulated and ptfe-polyimide-copper screening-silicon insulated.
Get CALLBACK

PTFE-Fiber Glass-Fiber Glass

PTFE-Fiber Glass-Fiber Glass
 
Ask For Price
Product Price:  
Get Latest Price

Product Details:
ConductorSolid, Multistrand, Thermocouple / Extension / Compensating Grade Materials as per ASTM E230 / 77 &
InsulationPTFE & Fiber Glass Insulation with high temperature Varnish
Operating Temp.400 DegreeC
Color CodeAccording to ANSI MC 96.1
Outer JacketFiber Glass Insulation with High Temp. Varnish.
Limit of ErrorAccording to ASTM E230 / 77, IEC 58

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

Yes! I am interested
Get CALLBACK

FEP-Almyler Screen-FEP-SS Braiding insulated

FEP-Almyler Screen-FEP-SS Braiding insulated
 
Ask For Price
Product Price:  
Get Latest Price

Product Details:
ConductorSolid, Multistrand, Copper Material
Core InsulationExtruded FEP Insulated
ScreeningAlmylar Screening with ATC Drain Wire
Color CodeAccording to DIN
Outer JacketExtruded FEP Insulated
Outer BraidingStainless Steel Wire
Operating Temp.200 DegreeC

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

Yes! I am interested
Get CALLBACK

Pfa Insulated Cable

Pfa Insulated Cable
 
Ask For Price
Product Price:  
Get Latest Price

Product Details:
InsulationExtruded PFA Insulation
Outer JacketExtruded PFA Insulated
Color CodeAccording to ANSI MC 96.1
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1
Operating Temp.260 DegreeC
Limit of ErrorAccording to ASTM E230 / 77 / IEC 584.

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

Yes! I am interested
Get CALLBACK

Polyimide-PTFE-Polyimide-PTFE-MICA-FG-SS Braiding insulated

Polyimide-PTFE-Polyimide-PTFE-MICA-FG-SS Braiding insulated
 
Ask For Price
Product Price:  
Get Latest Price

Product Details:
IsolatorPolyimide Tape
Operating Temp.450 DegreeC
Limit of ErrorAccording to ASTM E230 / 77 / IEC 584
Inner SheathPTFE Temperature Saturated
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1
InsulationPTFE Temperature Saturated
Overall BraidingStainless Wire Armouring
Outer SheathMica Tape / Fiber Glass with High Temp. Varnish
Color CodeAccording to ANSI MC 96.1

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

Yes! I am interested
Get CALLBACK

PTFE-MICA-Fiber Glass Insulated

PTFE-MICA-Fiber Glass Insulated
 
Ask For Price
Product Price:  
Get Latest Price

Product Details:
InsulationPTFE Insulation
Inner SheathPTFE Temperature Saturated
Outer SheathMica Tape / Fiber Glass with High Temp. Varnish
Operating Temp.350 DegreeC
Limit of ErrorAccording to ASTM E230 / 77, IEC 584
Color CodeAccording to ANSI MC 96.1
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230 / 77 & IEC5843

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

Yes! I am interested
Get CALLBACK

PTFE-Polyimide-Copper Screening-Silicon Insulated

PTFE-Polyimide-Copper Screening-Silicon Insulated
 
Ask For Price
Product Price:  
Get Latest Price

Product Details:
InsulationPTFE Insulation
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230/77 & IEC5843
IsolatorPolyimide Tape
ScreeningBare Copper / TPC/NPC/SPC
Outer JacketSilicon Insulation
Operating Temp.200 DegreeC
Limit of ErrorAccording to ASTM E230 / 77 / IEC 584
Color CodeAccording to IEC 5843

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

Yes! I am interested
Get CALLBACK

PTFE-Asbestos Braiding Insulated

PTFE-Asbestos Braiding Insulated
 
Ask For Price
Product Price:  
Get Latest Price

Product Details:
InsulationPTFE Insulation
Color CodeAccording to ANSI MC 96.1
Inner JacketPTFE Insulation
Outer JacketAsbestos Braiding
Operating Temp.300 DegreeC
Limit of ErrorAccording to ASTM E230 / 77 / IEC 584
ConductorSolid, Multistrand, Thermocouple / Extension / Compensating Grade Materials as per ASTM E230 / 77 &

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

Yes! I am interested
Get CALLBACK

PTFE - Polyimide - Copper Screening - PTFE Insulated

PTFE - Polyimide - Copper Screening - PTFE Insulated
 
Ask For Price
Product Price:  
Get Latest Price

Product Details:
Outer JacketPTFE Sheathed
Operating Temp.260 DegreeC
Limit of ErrorAccording to ASTM E230 / 77 / IEC 584
Color CodeAccording to ANSI MC 96.1
ConductorSolid, Multistrand, Thermocouple / Extension / Compensating Grade Materials as per ASTM E230 / 77 &
InsulationPTFE Insulation
IsolatorPolyimide Tape
ScreeningCopper Screening

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

Yes! I am interested
Get CALLBACK

PTFE -Steel Braiding Insulated

PTFE -Steel Braiding Insulated
 
Ask For Price
Product Price:  
Get Latest Price

Product Details:
InsulationPTFE Insulation
Operating Temp.260 DegreeC
Limit of ErrorAccording to ASTM E230 / 77 / IEC 584
ConductorSolid, Multistrand, Thermocouple / Extension / Compensating Grade Materials as per ASTM E230 / 77 &
Color CodeAccording to ANSI MC 96.1
Outer JacketPTFE Sheathed
Braiding(ArmouringStainless Steel Wire Braided Armoured

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

Yes! I am interested
Get CALLBACK

FEP-SS Braiding Insulated

FEP-SS Braiding Insulated
 
Ask For Price
Product Price:  
Get Latest Price

Product Details:
InsulationExtruded FEP Insulated
Outer JacketExtruded FEP Insulated
Outer BraidingStainless Steel Wire
Limit of ErrorAccording to ASTM E230 / 77 / IEC 584.
Color CodeAccording to ANSI MC 96.1
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1
Operating Temp.200 DegreeC

Ghaziabad Flopol Insulations Private Limited, are one of the leading manufacturer and supplier of all kinds PTFE Cable & Wire. All our products are at par with the highest quality standards. Apart from this, we also offer PTFE Insulated Cables, PTFE Tapes and Floor Heating Mats.
Yes! I am interested
Get CALLBACK

PTFE-PTFE Insulated

PTFE-PTFE Insulated
 
Ask For Price
Product Price:  
Get Latest Price

Product Details:
InsulationPTFE Insulation
Color CodeAccording to ANSI MC 96.1
ConductorSolid, Multistrand, Thermocouple/Extension/Compensating Grade Materials as per ASTM E230 / 77 & IEC5
Outer JacketPTFE Sheathed
Operating Temp.260 DegreeC
Limit of ErrorAccording to ASTM E230 / 77 / IEC 584

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

Yes! I am interested
Get CALLBACK

PTFE Twisted Pair

PTFE Twisted Pair
 
Ask For Price
Product Price:  
Get Latest Price

Product Details:
Cable TypeTwisted Pair
ConductorSolid, Multistranded Thermocouple/Extension/Compensating Grade Materials as per ASTM E230 / 77 & IEC
InsulationPTFE Insulation
Operating Temp.260 DegreeC
Limits of ErrorAccording to ASTM E230 / 77
Color CodeAccording to ANSI MC 96.1
Country of OriginMade in India

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

Yes! I am interested
Get CALLBACK

PFA-SS Braiding insulated

PFA-SS Braiding insulated
 
Ask For Price
Product Price:  
Get Latest Price

Product Details:
Limit Of ErrorAccording to ASTM E230 / 77 / IEC 584
Color CodeAccording to ANSI MC 96.1
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1
InsulationExtruded PFA Insulated
Outer BraidingStainless Steel Wire Braiding
Operating Temp.260 DegreeC

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

Yes! I am interested
Get CALLBACK

3 Core Rtd Cable

3 Core Rtd Cable
 
Ask For Price
Product Price:  
Get Latest Price

Product Details:
Temperature Range-50 to 250 deg C
Conductor MaterialAnnealed Bare Copper Conductor
Conductor SizeStranded AWG 24/7/32 (0.22 Sqmm)
No. of Core03
Colour CodeRed, Red, White
Sheath ColorWhite

Ghaziabad Flopol Insulations Private Limited, are one of the leading manufacturer and supplier of all kinds PTFE Cable & Wire. All our products are at par with the highest quality standards. Apart from this, we also offer PTFE Insulated Cables, PTFE Tapes and Floor Heating Mats.
Yes! I am interested
Get CALLBACK

Fiber Glass - Fiber Glass Insulated

Fiber Glass - Fiber Glass Insulated
 
Ask For Price
Product Price:  
Get Latest Price

Product Details:
Operating Temp.450 DegreeC
Limit of ErrorAccording to ASTM E230 / 77 / IEC 584
Color CodeAccording to ANSI MC 96.1
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1
InsulationBraided or Lapped Fiber with Silicon Varnish, High Temp. Saturated
Outer SheathBraided Fiber with Silicon Varnish, High Temp. Saturated

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.


Yes! I am interested
Get CALLBACK

Polyimide-Polyimide - 310 C

Polyimide-Polyimide - 310 C
 
Ask For Price
Product Price:  
Get Latest Price

Product Details:
Insulation ClassPolymide tape Insulation
Limit of ErrorAccording to ASTM E-230 /77 /IEC 584
Operating temperature310 degree C
ConductorSolid, multistrand, Thermocouple Grade Materials as per ASTM E230 and ANSI MC 96.1
ConstructionTwisted /Flat
Inner jacketpolymide insulation
Country of OriginMade in India

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.


Yes! I am interested
Get CALLBACK

Polyimide-Fiber Glass-Fiber Glass-Asbestos Braiding

Polyimide-Fiber Glass-Fiber Glass-Asbestos Braiding
 
Ask For Price
Product Price:  
Get Latest Price

Product Details:
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1
InsulationPolyimide-Fiber glass Insulated with High Temp. Varnish
Outer SheathBraided Fiber Glass with High Temp. Varnish
Overall BraidingAsbestos Braiding
Operating Temp.450 DegreeC
Limit of ErrorAccording to ASTM E230/77 / IEC 584
Color CodeAccording to ANSI MC 96.1

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.


Yes! I am interested
Get CALLBACK

Polyimide Twisted 310 C

Polyimide Twisted 310 C
 
Ask For Price
Product Price:  
Get Latest Price

Product Details:
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1
InsulationPolyimide Taped Insulation
Operating Temp.310 DegreeC
Color CodeAccording to ANSI MC 96.1
Limit of ErrorAccording to ASTM E230 / 77 / IEC 584

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

Yes! I am interested
Get CALLBACK

FEP-Polyimide-Copper Screening-FEP-SS Braiding

FEP-Polyimide-Copper Screening-FEP-SS Braiding
 
Ask For Price
Product Price:  
Get Latest Price

Product Details:
ScreeningCopper Screen
Overall CoveringStainless Steel Wire
Limit of ErrorAccording to ASTM E230/77 / IEC 584.
Color CodeAccording to ANSI MC 96.1
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1
Outer JacketExtruded FEP Insulated
InsulationExtruded FEP Insulated
IsolatorPolyimide Tape
Operating Temp.200 DegreeC

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

Yes! I am interested
Get CALLBACK

FEP-Polyimide-Copper Screening-FEP insulated

FEP-Polyimide-Copper Screening-FEP insulated
 
Ask For Price
Product Price:  
Get Latest Price

Product Details:
Outer JacketExtruded FEP Insulated
Operating Temp.200 DegreeC
Color CodeAccording to DIN
ConductorSolid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper, Tinned
ScreeningCopper Screening
Core InsulationExtruded FEP Insulated
IsolatorPolyimide

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

Yes! I am interested
Get CALLBACK

Alumina Fiber-Alumina Fiber insulated

Alumina Fiber-Alumina Fiber insulated
 
Ask For Price
Product Price:  
Get Latest Price

Product Details:
Limit Of ErrorAccording to ASTM E230 / 77 / IEC 584.
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1
InsulationAlumina Fiber Insulation
Outer JacketAlumina Fiber Insulation
Operating Temp.1200 DegreeC Maximum

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.


Yes! I am interested
Get CALLBACK

FEP- Almyler-FEP

FEP- Almyler-FEP
 
Ask For Price
Product Price:  
Get Latest Price

Product Details:
Operating Temp.200 DegreeC
Limit of ErrorAccording to ASTM E230/77 / IEC 584
Color CodeAccording to ANSI MC 96.1
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1
InsulationExtruded FEP Insulated
Outer BraidingAlmylar Screen with ATC Drain Wire
Outer JacketExtruded FEP Insulated

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

Yes! I am interested
Explore More Products
X
Find UsSunil Rastogi (CEO) Ghaziabad Flopol Insulations Private Limited
7 KM Milestone, Meerut Road Morta, Mainapur, Ghaziabad - 201003, Uttar Pradesh, India
SEND SMS
SEND E-MAIL