Call 08048968458 84% Response Rate

Send Enquiry

our range

Thermocouple Wire

Manufacturer of a wide range of products which include ptfe-fiber glass-fiber glass, polyimide-ptfe-polyimide-ptfe-mica-fg-ss braiding insulated, ptfe-mica-fiber glass insulated, ptfe-polyimide-copper screening-silicon insulated, ptfe - polyimide - copper screening - ptfe insulated and ptfe -steel braiding insulated.

PTFE-Fiber Glass-Fiber Glass

  • PTFE-Fiber Glass-Fiber Glass
  • PTFE-Fiber Glass-Fiber Glass
PTFE-Fiber Glass-Fiber Glass
Get Best Quote
Price on Request
ConductorSolid, Multistrand, Thermocouple / Extension / Compensating Grade Materials as per ASTM E230 / 77 &
InsulationPTFE & Fiber Glass Insulation with high temperature Varnish
Outer JacketFiber Glass Insulation with High Temp. Varnish.
Operating Temp.400 DegreeC
Limit of ErrorAccording to ASTM E230 / 77, IEC 58
Color CodeAccording to ANSI MC 96.1

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

View Complete details

Yes! I am Interested Request a call back

Polyimide-PTFE-Polyimide-PTFE-MICA-FG-SS Braiding insulated

  • Polyimide-PTFE-Polyimide-PTFE-MICA-FG-SS Braiding insulated
  • Polyimide-PTFE-Polyimide-PTFE-MICA-FG-SS Braiding insulated
Polyimide-PTFE-Polyimide-PTFE-MICA-FG-SS Braiding insulated
Get Best Quote
Price on Request
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1
InsulationPTFE Temperature Saturated
IsolatorPolyimide Tape
Inner SheathPTFE Temperature Saturated
Outer SheathMica Tape / Fiber Glass with High Temp. Varnish
Overall BraidingStainless Wire Armouring
Operating Temp.450 DegreeC
Limit of ErrorAccording to ASTM E230 / 77 / IEC 584
Color CodeAccording to ANSI MC 96.1

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

View Complete details

Yes! I am Interested Request a call back

PTFE-MICA-Fiber Glass Insulated

  • PTFE-MICA-Fiber Glass Insulated
  • PTFE-MICA-Fiber Glass Insulated
PTFE-MICA-Fiber Glass Insulated
Get Best Quote
Price on Request
InsulationPTFE Insulation
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230 / 77 & IEC5843
Inner SheathPTFE Temperature Saturated
Outer SheathMica Tape / Fiber Glass with High Temp. Varnish
Operating Temp.350 DegreeC
Limit of ErrorAccording to ASTM E230 / 77, IEC 584
Color CodeAccording to ANSI MC 96.1

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

View Complete details

Yes! I am Interested Request a call back

PTFE-Polyimide-Copper Screening-Silicon Insulated

  • PTFE-Polyimide-Copper Screening-Silicon Insulated
  • PTFE-Polyimide-Copper Screening-Silicon Insulated
PTFE-Polyimide-Copper Screening-Silicon Insulated
Get Best Quote
Price on Request
InsulationPTFE Insulation
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230/77 & IEC5843
IsolatorPolyimide Tape
ScreeningBare Copper / TPC/NPC/SPC
Outer JacketSilicon Insulation
Operating Temp.200 DegreeC
Limit of ErrorAccording to ASTM E230 / 77 / IEC 584
Color CodeAccording to IEC 5843

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

View Complete details

Yes! I am Interested Request a call back

PTFE - Polyimide - Copper Screening - PTFE Insulated

  • PTFE - Polyimide - Copper Screening - PTFE Insulated
  • PTFE - Polyimide - Copper Screening - PTFE Insulated
PTFE - Polyimide - Copper Screening - PTFE Insulated
Get Best Quote
Price on Request
ConductorSolid, Multistrand, Thermocouple / Extension / Compensating Grade Materials as per ASTM E230 / 77 &
InsulationPTFE Insulation
IsolatorPolyimide Tape
ScreeningCopper Screening
Outer JacketPTFE Sheathed
Operating Temp.260 DegreeC
Limit of ErrorAccording to ASTM E230 / 77 / IEC 584
Color CodeAccording to ANSI MC 96.1

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

View Complete details

Yes! I am Interested Request a call back

PTFE -Steel Braiding Insulated

  • PTFE -Steel Braiding Insulated
  • PTFE -Steel Braiding Insulated
PTFE -Steel Braiding Insulated
Get Best Quote
Price on Request
InsulationPTFE Insulation
ConductorSolid, Multistrand, Thermocouple / Extension / Compensating Grade Materials as per ASTM E230 / 77 &
Outer JacketPTFE Sheathed
Braiding(ArmouringStainless Steel Wire Braided Armoured
Operating Temp.260 DegreeC
Limit of ErrorAccording to ASTM E230 / 77 / IEC 584
Color CodeAccording to ANSI MC 96.1

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

View Complete details

Yes! I am Interested Request a call back

PTFE-PTFE Insulated

  • PTFE-PTFE Insulated
  • PTFE-PTFE Insulated
PTFE-PTFE Insulated
Get Best Quote
Price on Request
InsulationPTFE Insulation
ConductorSolid, Multistrand, Thermocouple/Extension/Compensating Grade Materials as per ASTM E230 / 77 & IEC5
Outer JacketPTFE Sheathed
Operating Temp.260 DegreeC
Limit of ErrorAccording to ASTM E230 / 77 / IEC 584
Color CodeAccording to ANSI MC 96.1

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

View Complete details

Yes! I am Interested Request a call back

FEP-Almyler Screen-FEP-SS Braiding insulated

  • FEP-Almyler Screen-FEP-SS Braiding insulated
  • FEP-Almyler Screen-FEP-SS Braiding insulated
FEP-Almyler Screen-FEP-SS Braiding insulated
Get Best Quote
Price on Request
ConductorSolid, Multistrand, Copper Material
Core InsulationExtruded FEP Insulated
ScreeningAlmylar Screening with ATC Drain Wire
Outer JacketExtruded FEP Insulated
Outer BraidingStainless Steel Wire
Operating Temp.200 DegreeC
Color CodeAccording to DIN

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

View Complete details

Yes! I am Interested Request a call back

PFA-SS Braiding insulated

  • PFA-SS Braiding insulated
  • PFA-SS Braiding insulated
PFA-SS Braiding insulated
Get Best Quote
Price on Request
Limit Of ErrorAccording to ASTM E230 / 77 / IEC 584
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1
InsulationExtruded PFA Insulated
Outer BraidingStainless Steel Wire Braiding
Operating Temp.260 DegreeC
Color CodeAccording to ANSI MC 96.1

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

View Complete details

Yes! I am Interested Request a call back

PTFE Twisted Pair

  • PTFE Twisted Pair
  • PTFE Twisted Pair
  • PTFE Twisted Pair
PTFE Twisted Pair
Get Best Quote
Price on Request
Cable TypeTwisted Pair
Country of OriginMade in India
ConductorSolid, Multistranded Thermocouple/Extension/Compensating Grade Materials as per ASTM E230 / 77 & IEC
InsulationPTFE Insulation
Operating Temp.260 DegreeC
Limits of ErrorAccording to ASTM E230 / 77
Color CodeAccording to ANSI MC 96.1

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

View Complete details

Yes! I am Interested Request a call back

FEP-SS Braiding Insulated

FEP-SS Braiding Insulated
Get Best Quote
Price on Request
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1
InsulationExtruded FEP Insulated
Outer JacketExtruded FEP Insulated
Outer BraidingStainless Steel Wire
Operating Temp.200 DegreeC
Limit of ErrorAccording to ASTM E230 / 77 / IEC 584.
Color CodeAccording to ANSI MC 96.1
Ghaziabad Flopol Insulations Private Limited, are one of the leading manufacturer and supplier of all kinds PTFE Cable & Wire. All our products are at par with the highest quality standards. Apart from this, we also offer PTFE Insulated Cables, PTFE Tapes and Floor Heating Mats.

View Complete details

Yes! I am Interested Request a call back

FEP-Polyimide-Copper Screening-FEP insulated

  • FEP-Polyimide-Copper Screening-FEP insulated
  • FEP-Polyimide-Copper Screening-FEP insulated
FEP-Polyimide-Copper Screening-FEP insulated
Get Best Quote
Price on Request
ConductorSolid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper, Tinned
Core InsulationExtruded FEP Insulated
IsolatorPolyimide
ScreeningCopper Screening
Outer JacketExtruded FEP Insulated
Operating Temp.200 DegreeC
Color CodeAccording to DIN

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

View Complete details

Yes! I am Interested Request a call back

FEP- Almyler-FEP

  • FEP- Almyler-FEP
  • FEP- Almyler-FEP
FEP- Almyler-FEP
Get Best Quote
Price on Request
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1
InsulationExtruded FEP Insulated
Outer BraidingAlmylar Screen with ATC Drain Wire
Outer JacketExtruded FEP Insulated
Operating Temp.200 DegreeC
Limit of ErrorAccording to ASTM E230/77 / IEC 584
Color CodeAccording to ANSI MC 96.1

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

View Complete details

Yes! I am Interested Request a call back

3 Core Rtd Cable

  • 3 Core Rtd Cable
  • 3 Core Rtd Cable
  • 3 Core Rtd Cable
3 Core Rtd Cable
Get Best Quote
Price on Request
Temperature Range-50 to 250 deg C
Conductor MaterialAnnealed Bare Copper Conductor
Conductor SizeStranded AWG 24/7/32 (0.22 Sqmm)
No. of Core03
Colour CodeRed, Red, White
Sheath ColorWhite
Ghaziabad Flopol Insulations Private Limited, are one of the leading manufacturer and supplier of all kinds PTFE Cable & Wire. All our products are at par with the highest quality standards. Apart from this, we also offer PTFE Insulated Cables, PTFE Tapes and Floor Heating Mats.

View Complete details

Yes! I am Interested Request a call back

Polyimide-Polyimide - 310 C

  • Polyimide-Polyimide - 310 C
  • Polyimide-Polyimide - 310 C
  • Polyimide-Polyimide - 310 C
Polyimide-Polyimide - 310 C
Get Best Quote
Price on Request
Insulation ClassPolymide tape Insulation
Country of OriginMade in India
Operating temperature310 degree C
Inner jacketpolymide insulation
Limit of ErrorAccording to ASTM E-230 /77 /IEC 584
ConstructionTwisted /Flat
ConductorSolid, multistrand, Thermocouple Grade Materials as per ASTM E230 and ANSI MC 96.1

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.


View Complete details

Yes! I am Interested Request a call back

FEP-Polyimide-Copper Screening-FEP-SS Braiding

  • FEP-Polyimide-Copper Screening-FEP-SS Braiding
  • FEP-Polyimide-Copper Screening-FEP-SS Braiding
  • FEP-Polyimide-Copper Screening-FEP-SS Braiding
FEP-Polyimide-Copper Screening-FEP-SS Braiding
Get Best Quote
Price on Request
InsulationExtruded FEP Insulated
IsolatorPolyimide Tape
Operating Temp.200 DegreeC
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1
ScreeningCopper Screen
Outer JacketExtruded FEP Insulated
Overall CoveringStainless Steel Wire
Limit of ErrorAccording to ASTM E230/77 / IEC 584.
Color CodeAccording to ANSI MC 96.1

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

View Complete details

Yes! I am Interested Request a call back

Fiber Glass - Fiber Glass Insulated

  • Fiber Glass - Fiber Glass Insulated
  • Fiber Glass - Fiber Glass Insulated
Fiber Glass - Fiber Glass Insulated
Get Best Quote
Price on Request
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1
InsulationBraided or Lapped Fiber with Silicon Varnish, High Temp. Saturated
Outer SheathBraided Fiber with Silicon Varnish, High Temp. Saturated
Operating Temp.450 DegreeC
Limit of ErrorAccording to ASTM E230 / 77 / IEC 584
Color CodeAccording to ANSI MC 96.1

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.


View Complete details

Yes! I am Interested Request a call back

Pfa Insulated Cable

  • Pfa Insulated Cable
  • Pfa Insulated Cable
Pfa Insulated Cable
Get Best Quote
Price on Request
InsulationExtruded PFA Insulation
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1
Outer JacketExtruded PFA Insulated
Operating Temp.260 DegreeC
Limit of ErrorAccording to ASTM E230 / 77 / IEC 584.
Color CodeAccording to ANSI MC 96.1

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

View Complete details

Yes! I am Interested Request a call back

Polyimide-Fiber Glass-Fiber Glass-Asbestos Braiding

  • Polyimide-Fiber Glass-Fiber Glass-Asbestos Braiding
  • Polyimide-Fiber Glass-Fiber Glass-Asbestos Braiding
Polyimide-Fiber Glass-Fiber Glass-Asbestos Braiding
Get Best Quote
Price on Request
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1
InsulationPolyimide-Fiber glass Insulated with High Temp. Varnish
Outer SheathBraided Fiber Glass with High Temp. Varnish
Overall BraidingAsbestos Braiding
Operating Temp.450 DegreeC
Limit of ErrorAccording to ASTM E230/77 / IEC 584
Color CodeAccording to ANSI MC 96.1

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.


View Complete details

Yes! I am Interested Request a call back

Polyimide Twisted 310 C

  • Polyimide Twisted 310 C
  • Polyimide Twisted 310 C
Polyimide Twisted 310 C
Get Best Quote
Price on Request
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1
InsulationPolyimide Taped Insulation
Operating Temp.310 DegreeC
Limit of ErrorAccording to ASTM E230 / 77 / IEC 584
Color CodeAccording to ANSI MC 96.1

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

View Complete details

Yes! I am Interested Request a call back

PTFE-Asbestos Braiding Insulated

  • PTFE-Asbestos Braiding Insulated
  • PTFE-Asbestos Braiding Insulated
PTFE-Asbestos Braiding Insulated
Get Best Quote
Price on Request
InsulationPTFE Insulation
ConductorSolid, Multistrand, Thermocouple / Extension / Compensating Grade Materials as per ASTM E230 / 77 &
Inner JacketPTFE Insulation
Outer JacketAsbestos Braiding
Operating Temp.300 DegreeC
Limit of ErrorAccording to ASTM E230 / 77 / IEC 584
Color CodeAccording to ANSI MC 96.1

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.

View Complete details

Yes! I am Interested Request a call back

Alumina Fiber-Alumina Fiber insulated

  • Alumina Fiber-Alumina Fiber insulated
  • Alumina Fiber-Alumina Fiber insulated
Alumina Fiber-Alumina Fiber insulated
Get Best Quote
Price on Request
Limit Of ErrorAccording to ASTM E230 / 77 / IEC 584.
ConductorSolid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1
InsulationAlumina Fiber Insulation
Outer JacketAlumina Fiber Insulation
Operating Temp.1200 DegreeC Maximum

Thermocouple Cables are used to measure the temperature directly.

Thermocouple Extension or Compensating wires are only used to extend a thermocouple signal from a sensor to an instrument for readings.


View Complete details

Yes! I am Interested Request a call back

EXPLORE MORE CATEGORIES